Move touch probe to leaf top corner set datum (0.0.0) Input program as below ⇐ ПредыдущаяСтр 2 из 2 L X0 Y0 Z0 R0 F5000 L X32.5 R0 F1000 L X-32.5 L X0 L Y32.5 L Y-32.5 L Y0 L Z250 USE before I give you procedural only cancel A90° measure!! ※If you don’t want take out 600*500 table please follow below procedural. About wrong picture we will modify in further. now just follow please!! 2.Use 150mm gauge measure spindle nose to C axis 600*500 table distance EXP:Z DATUM=-479.0 MP7530.2=-479.0+(-150.0)=-629.0 4. Program Tool CALL”1 “Cycle start install Touch probe in spindle use same gauge measure probe length insert data to Tool table NO” 1” Executes TOOL CALL 1 Z by MDI mode (Read tool “1”compensation)
5.Install a square parts on table make parallel with X axis .Move tool probe tip to rear of parts . X axis keep on machine coordinate 0.000 position .let Y direction touch 0.10~0.15mm only .set datum X0/Y0/Z0. 0° 6. Input program as below: TOOL CALL 1 Z L X0 Y0 ZO C0 A0 R0 F2000 M128 C90.F1000 C180. C270. C360. Z200. M129 Measure 4 direction date compensation MP960 X & Y until all data is close . 90° 180° 270° 360°
Move touch probe to leaf top corner set datum (0.0.0) Input program as below
|